  low signal relay g6s 79 low signal relay g6s suface mount dpdt relay ? high dielectric withstand voltage of 2,000 vac between coil and contacts (standard type); 1,500 vac between contacts of different polarity. ? meets fcc part 68 and telcor dia 2.5 kv surge withstand. ? european version certified for en60950/en41003 supple- mentary insulation at 250 v at pollution degree 2. ? low power consumption of 140 mw (non-latching) ? available in through-hole and smt terminals. ? tape and reel or tube packaging. ? rohs compliant. ordering information standard version . * certified for en60950/en41003 supplementary insulation at 250 v (pollution degree 2) model number legend terminal model contact form non-latching single coil latching dual coil latching standard european version* gull-wing dpdt g6s-2f g6s-2f-y G6SU-2F g6sk-2f inside ?l? g6s-2g g6s-2g-y g6su-2g g6sk-2g pcb through-hole g6s-2 g6s-2-y g6su-2 g6sk-2 rated coil v oltage notes: 1. w hen ordering, add the rated coil v oltage to the model n u m b er. example: g6s-2f dc12 2. w hen ordering tape packing (s u rface mo u nt models), add "-tr" to the model n u m b er. w hen ordering high-sensiti v ity d u al coil latching models, add "-h? to the model n u m b er. example: g6s-2f-tr dc12 "-tr" is not part of the relay model n u m b er. therefore, it is not marked on the relay case. tape packing 3. d u al coil latching models are a v aila b le w ith a high-sensiti v ity coil. (140 m w ; 200 m w for dc24) example: g6sk-2g-h-tr dc5 high-sensiti v ity coil 1. relay function n one: n on-latching u: single coil latching k: d u al coil latching 2. contact form 2: dpdt 3. terminal shape n one: thro u gh-hole f: g u ll- w ing s u rface mo u nt g: inside ?l? s u rface mo u nt 4. approved standards n one: ul/csa y: e n 60950/e n 41003 (standard coil models - 5, 12, 24 v dc ) 5. packa g in g n one: t ub e packaging tr: tape and reel packaging (s u rface mo u nt models) 6. rated coil volta g e 3, 4.5, 5, 12, 24 v dc g6s - - - dc 4 5 1 3 2 6
80 low signal relay g6s specification contact data note: p level: 60 = 0.1 x 10 -6 /operation this value was measured at a switching frequency of 120 operat ions/min and the criterion of contact resistance is 50 . this value may vary depending on the operating environment. always double-check re lay suitability under actu al operating conditions. coil data g6s - standard non-latching (g6s-2f, g6s-2g, g6s-2) g6su - standard single coil latching (G6SU-2F, g6su-2g, g6su-2) g6sk - standard dual coil latc hing (g6sk-2f, g6sk-2g, g6sk-2) g6s - european version, non-latching (g6s-2f-y, g6s-2g-y, g6s-2-y) note: 1. the rated current and coil resistance ar e measured at a coil temperature of 23 c with a tolerance of 10%. 2. the operating characteristics are m easured at a coil temperature of 23 c. 3. pick-up voltage will vary with temperature. 4. the maximum voltage is the highest voltage that can be imposed on the relay coil. load resistive load (cos = 1) rated load 0.5 a at 125 vac 2 a at 30 vdc contact material ag (au clad) max. carry current 2 a max. operating voltage 250 vac, 220 vdc max. operating current 2 a max. switching capacity 62.5 va, 60 w min. permissible load 10 a, 10 mvdc rated voltage (vdc) rated current (ma) coil resistance ( ) pick-up voltage dropout voltage maximum voltage power consumption (mw) % of rated voltage 3 46.7 64.3 75% max. 10% min. 200% max.@ 23 c approx. 140 4.5 31.0 145 5 28.1 178 12 11.7 1,028 24 8.3 2,880 170% max.@ 23 c approx. 200 rated voltage (vdc) rated current (ma) coil resistance ( ) coil inductance (h) (ref. value) set pick-up voltage reset pick-up voltage maximum volt- age power consumption (mw) armature off armature on % of rated voltage 3 33.3 90 0.108 0.069 75% max. 75% max. 180% max. @ 23 c approx. 100 4.5 22.2 203 0.27 0.14 5 20.0 250 0.36 0.18 12 8.3 1,440 2.12 1.14 24 6.3 3,840 5.80 3.79 approx. 150 rated voltage (vdc) rated current (ma) coil resistance ( ) coil inductance (h) (ref. value) set pick-up voltage reset pick-up voltage maximum voltage power consumption (mw) set reset armature off armature on armature off armature on % of rated voltage 3 66.6 45 0.045 0.035 0.032 0.045 75% max. 75% max. 170% max. @ 23 c approx. 200 4.5 44.4 101 0.12 0.074 0.082 0.14 5 40 125 0.14 0.088 0.098 0.16 12 16.7 720 0.60 0.41 0.46 0.54 24 12.5 1,920 1.98 1.23 1.34 2.23 140% max. @ 23 c approx. 300 rated voltage (vdc) rated current (ma) coil resistance ( ) pick-up voltage dropout voltage maximum voltage power consumption (mw) % of rated voltage 5 40.0 125 75% max. 10% min. 170% max.@ 23 c approx. 200 12 16.7 720 24 9.6 2,504 approx. 230
low signal relay g6s 81 characteristics note: 1. the contact resistance was measured with 10 ma at 1 vdc with a voltage drop method. 2. values in parentheses are typica l values unless otherwise stated. 3. the insulation resistance was measured with a 500-vdc megohmme ter applied to the same parts as those used for checking the dielectric strength (except between the set and reset coil). 4. data shown are of initial value. characteristic data service life contact resistance (see note 1) 75 m max. operate (set) time (see note 2) 4 ms max. (mean value approx. 2.5 ms g6s; 2.0 ms g6su, g6sk) release (reset) time (see note 2) 4 ms max. (mean value approx. 1.5 ms g6s; 2.0 ms g6su, g6sk) bounce time approx. 0.5 ms max. operating frequency mechanical: 36,000 operations/hr electrical: 1,800 operations/hr (under rated load) insulation resistance (see note 3) 1,000 m min. (at 500 vdc) dielectric strength 2,000 vac, 50/60 hz for 1 minute (g6s, g6su) between coil and contacts 1,000 vac, 50/60 hz for 1 minute (g6sk) between coil and contacts 1,500 vac, 50/60 hz for 1 minute between contacts of different poles 1,000 vac, 50/60 hz for 1 minute between contacts of same pole 500 vac, 50/60 hz for 1 minute between set and reset coils (g6sk) surge withstand voltage conforming to telcordia specs. 2,500 v (2 x 10 s) between coil and contacts for g6s and g6su 2,500 v (2 x 10 s) between contacts of different poles conforming to fcc part 68 1,500 v (10 x 160 s) between coil and contacts for g6sk 1,500 v (10 x 160 s) between contacts of same pole vibration mechanical durability 10 to 55 hz; 5 mm double amplitude malfunction durability 10 to 55 hz; 3.3 mm double amplitude shock mechanical durability 1,000 m/s 2 ; approx. 100 g malfunction durability 750 m/s 2 ; approx. 75 g ambient temperature -40 to +85 c with no icing; -40 to +70 c with no icing (g6sk, dc24 coil) ambient humidity 5% to 85% rh service life mechanical 100,000,000 operations min. (at 36,000 operations/hour) electrical 100,000 operations min. (2a@30vdc, resistive; 1,200 ops/hr.) 100,000 operations min. (0.5a@125vac, resistive) see ?characteristic data? weight approx. 2g 0 0.2 30 10 20 1000 500 300 100 200 50 1.0 0.8 0.6 0.4 service life (x10 6 operations) resistive load: 10 ma, 10 vdc ambient temperature: +85? contact resistance (m ) 0 0.1 30 10 20 1000 500 300 100 200 50 0.5 0.4 0.3 0.2 service life (x10 6 operations) resistive load: 100 ma, 28 vdc ambient temperature: +85? contact resistance (m ) 0 0.2 30 10 20 1000 500 300 100 200 50 1.0 0.8 0.6 0.4 service life (x10 6 operations) resistive load: 100 ma, 50 vdc ambient temperature: +85? contact resistance (m )
82 low signal relay g6s maximum switchin g capacity sin g le coil latchin g dual coil latchin g s w itching c u rrent (a) s w itching v oltage ( v )am b ient temperat u re ( c) maxim u m coil v oltage ( % ) ambient temperature vs. maximum coil volta g e non-latchin g am b ient temperat u re ( c) maxim u m coil v oltage ( % ) g6su g6sk 12 v dc max. g6sk 24 v dc ac resisti v e load dc resisti v e load 12 v dc max. 24 v dc (g6s-y, 12 v dc max.) reference data ambient temperature vs. switchin g current non-latchin g s w itching c u rrent (a) sin g le coil latchin g dual coil latchin g am b ient temperat u re ( c) g6su 12 v dc max. g6su 24 v dc g6sk 12 v dc max. g6sk 24 v dc operating c u rrent (a) am b ient temperat u re ( c) 12 v dc max. 24 v dc (g6s-y) 24 v dc (g6s-y, 12 v dc max.) 24 v dc (g6s-y) note: the maxim u m coil v oltage refers to the maxim u m v al u e in a v arying range of operating po w er v oltage, not a contin u o u s v oltage. 0 0.4 30 10 500 300 100 70 200 50 2.0 1.6 1.2 0.8 rated operating current (a) service life (x10 4 operations) 30 vdc 125 vac 10 1000 1500 2000 2500 3000 3500 20 30 0 40 50 between coil and contacts breakdown voltage (v) number of contacts (pcs.) 10 1000 1500 2000 2500 3000 3500 20 30 0 40 50 between contacts of same pole. between contacts of different poles breakdown voltage (v) number of contacts (pcs.) electrical service life dielectric streng th (standard versio n, non-latching) detecting current: 1ma
low signal relay g6s 83 impulse withstand voltage (standard version, non-latching) impulse withstand volt age (european version) dielectric strength (europea n version, non-latching) 3 3500 4000 4500 5000 5500 6000 6 0 9 number of contacts (pcs.) breakdown voltage (v) between coil and contacts 5 1500 2000 2500 3000 3500 4000 10 0 15 number of contacts (pcs.) breakdown voltage (v) between contacts of same pole 3 3500 4000 4500 5000 5500 6000 6 0 9 number of contacts (pcs.) breakdown voltage (v) between coil and contacts between contacts of different poles (2 x 10 s) (10 x 160 s) (10 x 160 s) 3 4000 4500 5000 5500 6000 6500 6 0 9 number of contacts (pcs.) breakdown voltage (v) between coil and contacts between contacts of different poles 5 1500 2000 2500 3000 3500 4000 10 0 15 number of contacts (pcs.) breakdown voltage (v) between contacts of same pole 3 4000 4500 5000 5500 6000 6500 6 0 9 number of contacts (pcs.) breakdown voltage (v) between coil and contacts between contacts of different poles (2 x 10 s) (10 x 160 s) (10 x 160 s) 10 1500 2000 2500 3000 3500 4000 20 30 0 40 50 number of contacts (pcs.) breakdown voltage (v) between coil and contacts 10 1500 2000 2500 3000 3500 4000 20 30 0 40 50 number of contacts (pcs.) breakdown voltage (v) between contacts of different poles between contacts of same pole detecting current: 1ma
84 low signal relay g6s dimensions note: 1. all units are in millimeters unless otherwise indicated. 2. coplanarity is 0.1 mm max. standard orientation mark g6s-2, g6s-2-y tolerance: 0.3 footprint (bottom view) tolerance: 0.1 terminal arran g ement/ internal connections (bottom view) g6s-2g, g6s-2g-y tolerance: 0.3 footprint (top view) tolerance: 0.1 terminal arran g ement/ internal connections (top view) orientation mark g6s-2f, g6s-2f-y tolerance: 0.3 footprint (top view) tolerance: 0.1 terminal arran g ement/ internal connections (top view) eight, 1-dia. holes orientation mark
low signal relay g6s 85 single coil latching g6su-2 tolerance: 0.3 footprint (bottom view) tolerance: 0.1 terminal arran g ement/ internal connections (bottom view) g6su-2g tolerance: 0.3 footprint (top view) tolerance: 0.1 terminal arran g ement/ internal connections (top view) orientation mark 7.3+0.2 7.3+0.2 orientation mark G6SU-2F tolerance: 0.3 footprint (top view) tolerance: 0.1 terminal arran g ement/ internal connections (top view) eight, 1-dia. holes orientation mark
86 low signal relay g6s dual coil latching recommended soldering method g6sk-2 tolerance: 0.3 footprint (bottom view) tolerance: 0.1 terminal arran g ement/ internal connections (bottom view) g6sk-2g tolerance: 0.3 footprint (top view) tolerance: 0.1 terminal arran g ement/ internal connections (top view) orientation mark orientation mark 7.3+0.2 g6sk-2f tolerance: 0.3 footprint (top view) tolerance: 0.1 terminal arran g ement/ internal connections (top view) ten, 1-dia. holes orientation mark (1) irs method (mountin g solder: lead) time (s) temperat u re ( c) soldering preheating (2) irs method (mountin g solder: lead-free) temperat u re ( c) time (s) 250 max. 230 1 8 0 150 soldering preheating preheating soldering upper s u rface of case (peak): 255c max. 120 max. 30 max. note: the temperat u re profile indicates the temperat u re on the pcb. relay terminal section 220 to 240 1 8 0 to 200 150 90 to 120 20 to 30
low signal relay g6s 87 packaging tape and reel dimensions (surface mount models) ? tape type: te2416r (refer to eiaj - electronic industrial association of japan) ? reel type: r24e (refer to eiaj - el ectronic industrial association of japan) ? relays per reel: 400 ? reels per packing carton: 2 (800 relays) approvals ul recognized (file no. e41 515) / csa certified (file no. lr31928) - - ambient temp. = 40 c en60950 / en41003 note: 1. the rated values approved by each of the safety standards (e.g ., ul and csa) may be different fr om the performance characterist ics individually defined in this catalog. 2. in the interest of product improvement, specifications are subject to change. tube packing standard nomenclature 50 pcs per anti-static tube tape packing (surface mount versions) when ordering, add ?tr? before the rated coil voltage (e.g., g6s-2f- tr -dc12) note: tr is not part of the relay model number and will not be marked on the relay. type contact form coil rating contact ratings number of test operations g6s-2, g6s-2f, g6s-2g dpdt 2 to 48 vdc 3 a at 30 vdc (resistive) 0.3 a at 110 vdc (resistive) 0.5 a at 125 vac (general use) 6,000 g6su-2, G6SU-2F, g6su-2g g6sk-2, g6sk-2f, g6sk-2g g6sk-2-y, g6sk-2f-y, g6sk-2g-y 2 to 24 vdc type contact form isolation category voltage g6s-2-y, g6s-2f-y, g6s-2g-y dpdt supplementary isolation 250 vac g6s-2f, G6SU-2F, g6sk-2f, g6s-2f-y g6s-2g, g6su-2g, g6sk-2g, g6s-2g-y cover tape emboss tape carrier tape 13 0.2 2 10.5 2 0.3 29.5 1.0 25.5 0.5 r1.0 330 80 feed direction orientation mark
88 low signal relay g6s precautions ? use a dc power supply with 5% or less ripple factor to operate the coil. ? do not use the g6s where subject to strong external magnetic fields. ? do not use the g6s where subject to magnetic particles or excessive amounts of dust . ? do not reverse the polarity of the coil (+, ? ). ? latching types are delivered in t he reset position. we recommend that a reset voltage be applied in advance to start operation. ? do not drop the g6s or otherwise subject it to excessive shock. ? remove the relay from the packing immediately prior to usage. correct use long-term continuously on contacts using the relay in a circuit wher e the relay will be on continuously for long periods (without switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation, causing a film to develop on the contact surfaces. we recommend using a latching relay (magnetic-holding relay) in this kind of circuit. if a single-side stable model must be us ed in this kind of circuit, we rec- ommend using a fail-safe circuit design that provides protection against contact failure or coil burnout. relay handling use the relay as soon as possible after opening the moisture-proof package. if the relay is left for a long time after opening the mois- ture-proof package, the appearance may suffer and seal failure may occur after the solder mounting process. to store the relay after opening the moisture-proof package, pl ace it into the original pack- age and sealed the package with adhesive tape. when washing the product after soldering the relay to a pcb, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature to less than 40c. do not put the relay in a cold clean- ing bath immediately after soldering. claw securing force du ring automatic mounting during automatic insertion of relays, be sure to set the securing force of each claw to the following so that the relay?s characteristics will be maintained. g6s (k) (-u) -2 soldering ? soldering temperature: approx. 250 c (at 260 c if the dws method is used.) ? soldering time: approx. 5 s max. (approx. 2 s for the first time and approx. 3 s for the second time if the dws method is used.) ? be sure to adjust the level of the molten solder so that the solder will not overflow onto the pcb. g6s (k) (-u) -2f soldering the thickness of cream solder to be applied should be within a range between 150 m and 200 m on omron?s recommended pcb pattern . in order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left side. visually check that the relay is properly soldered. a c b dimension a: 1.96 n max. dimension b: 4.90 n max. dimension c: 1.96 n max. ins u fficient amo u nt of solder excessi v e amo u nt of solder heel fillet is formed solder pcb land terminal relay correct solderin g incorrect solderin g
low signal relay g6s memo
low signal relay g6s omron on-line global - http://www.omron.com usa - http://www.components.omron.com cat. no. x301-e-1c printed in usa omron electronic components llc 55 e. commerce drive, suite b schaumburg, il 60173 847-882-2288 10/12 specificat ions subject to change without notice all sales are subject to omron electronic components llc standard terms and conditions of sale, which can be found at http://www.components.omron.com/compon ents/web/webfiles.ns f/sales_terms.html all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.0393 7. to convert grams into ounces, multiply by 0.03527.


▲Up To Search▲   

 
Price & Availability of G6SU-2F

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X